Fire Alarm Control Panel
Conventional Fire Alarm Control Panel
White Conventional RE-9012 Ravel 12 Zone Fire Alarm Panel
System Components | Fire Alarm Control Panel |
Brand | RAVEL |
Type | Conventional |
Body Material | M S Body |
Color | White |
Model Name/Number | RE-9012 |
Product Specification
Brand | RAVEL |
System Components | Fire Alarm Control Panel |
Type | Conventional |
Usage/Application | FIRE ALARM SYSTEM |
Body Material | M S Body |
Color | Grey |
Model Name/Number | RE-9012 |
Minimum Order Quantity | 1 Piece |
Product Description
Ravel re-9012 12 zone fire alarm panel
zone name diffiene
keypad available
Conventional Fire Alarm System
Product Specification
Brand | Eurofyre |
Body Material | Plastic |
Mounting Type | Wall Mounted |
Power Source | Electric |
Frequency | 50 – 60 Hz |
Surface Finish | Coated |
Ravel Grey Conventional Fire Alarm Control Panel
- Complies with UL -864 and NFPA-72.
- 20 x 4 Dot Matrix LCD Display.
- Operates on 120 – 220v 60 /50 Hz, AC Mains power supply.
- Standby (battery) backup 24v DC power supply with builtin charger.
System Components | Fire Alarm Control Panel |
Brand | Ravel |
Type | Conventional |
Usage/Application | Office, Industrial, Commercial |
Color | Grey |
Automation Grade | Automatic |
Voltage | 120 – 220 V AC |
Dimensions | 425 x 350 x 120 mm |
Alarm Current | 15 – 30 mA |
Frequency | 60 / 50 Hz |
No Of Relays | 2 |
Maximum Loop Resistance | 100 ohms |
Line Drop | 1.8 V |
End-Of-Line Resistor | 4K7, 1/2 Watt |
Power Factor | 1.0 |
Charging Voltage | 28.0 V, +-0.5 V |
Charging Current | 1.2 A (Max) |
- Complies with UL -864 and NFPA-72.
- 20 x 4 Dot Matrix LCD Display.
- Operates on 120 – 220v 60 /50 Hz, AC Mains power supply.
- Standby (battery) backup 24v DC power supply with builtin charger.
- Touch Keypad for user friendly operation.
- Epoxy powder coated finish.
- Class- B, Style B / C initiating device circuit (IDC).
- All zones accept smoke detectors and any normally open contact device.
- Class B Notification Appliance Circuits (NAC).
- NAC shall be programmed as auto silence / Silence Inhibit.
- Error free Fire / Fault status in unambiguous colored LED indication.
- 1000 Event storage with RTC.
- Main, Standby status with audible and visual indication.
- Two Form C relays for fire and fault.
- Resettable / Steady 24V D.C. Output.
- RS 485 Communication facility.
- TCP/IP facility (Optional)
- MODBUS for BMS integration (Optional).
- PC software (optional)
- External Zone Wise Sounder/Contact via RS 485 (Optional).
- All field wiring circuits are supervised.
- Zone Isolation facility with loop voltage cut off.
- Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128.
- Facility to connect Public Address System (PA) through RS-485 Communication.
- Peer to Peer network facility.
- Maximum 16 panels can be connect in a Single Network.
Addressable Fire Alarm Control Panel
Bosch FPA 1000 Analog Addressable Fire Panels, For Office
- Suited to a wide range of applications and compatible with the latest Bosch solutions -including 440 Series Multi-criteria detectors.
- Peer-to-peer networking of up to eight -V2 panels in a single group.
Usage/Application | Office |
Brand | BOSCH |
Model | FPA 1000 |
Primary Voltage | 120 V AC or 240 V AC |
Secondary Voltage | 24 V DC |
Current consumption (standby) | 1.25 A maximum |
Battery Capacity | 7.0 Ah minimum,40 Ah maximum |
Charge Current | 2.0 A Maximum |
Fuse | 15 A Blade-type |
Line Impedance | 1.45 Ohm Maximum |
- Suited to a wide range of applications and compatible with the latest Bosch solutions -including 440 Series Multi-criteria detectors.
- Peer-to-peer networking of up to eight -V2 panels in a single group.
- Two on-board NACs and dual-line PSTN DACT.
- Built-in Ethernet connector for web-browser based programming and Conettix Alarm-over-IP communication.
- Support for up to 508 points on two analog addressable loops.
Analog Addressable Fire Alarm Control Panel
We provide our clients Analog Addressable Fire Alarm Control Panel that are designed to withstand every climatic conditions. These are automatic fire detection & wireless fire alarm system that consist of fire detectors and manual call points positioned in loops through out a building. Procured from well reputed sources, our cost effective range is appreciated for high performance and efficient functioning.
Product Type | Alarm Control Panel |
Usage/Application | Hotel, Bank, Hostels etc |
processo | 32 bit processor Arm Cortex M3. |
Mode | Day / Night Mode |
Battery Backup | 24VDC With Built In Charger. |
maintenance | Less Maintenance |
Features:
- Easy to operate
- Less maintenance
- Shock proof
Uses:
- Hostel
- Banks
- Hotel
Bosch FPA-5000 EN54 Addressable Fire Panel, For Industrial
The Fire Panel is Available with Two Different Housings:
- Housing for mounting directly on the wall
- Frame installation housings which are fitted to the mounting frame and can be swiveled.
- With the aid of special mounting kits, the housings can be mounted in 482.6 mm (19″) cabinets. All housings can be extended with various additional housings for all conceivable application
Brand | BOSCH |
Depth | 149 mm |
Height | 638 mm |
Model Number | FPA-5000 |
Width | 440 mm |
Product Type | Fire Alarm Control Panel |
Color | Black |
Features:
- Modular configuration allowing for easy extension
- Interconnection of up to 32 Panel Controllers, Remote Keypads, and OPC servers
- Multiple CAN loop connection with high- performance Ethernet backbone and redundancy
- Installation and auto-detection of functional modules by simply plugging them into the panel rail
- Connection to BIS Building Integration System via OPC server
Functions:
Operation / Processing of Messages:
The operation and the processing of all messages are easy and intuitive thanks to the ergonomically- designed control panel with its TFT touch???screen offering a menu-driven handling and multi-color display. To that end, there are permanently located keys on the right, bottom, and upper edge of the display as well as variably located virtual keys in the touch-screen area.
Modular Structure of the FPA???5000 Modular Fire Panel:
Due to its modular structure, the FPA???5000 Modular Fire Panel provides complete flexibility and thus customized solutions for any application.
Modules:
The functional modules are autonomous, encapsulated units that can be inserted into any control panel slot using “plug-and-play” technology. Thus, the power supply and the data traffic to the control panel are indicated automatically without any additional settings. The module is automatically identified by the control panel and functions in the default operating.
Wiring to external components is performed using compact connector/screw terminals. After a replacement, only the connectors need to be reinserted; extensive rewiring is no longer required. defined as network node or local node. Within a group, only panel conditions of the same group can be displayed. Regardless of the groups, network nodes allow for the display and handling of all panel conditions. Local nodes display the conditions of the related panel.
Detection Points:
The Address Cards activate detection points. The FPA???5000 governs up to 4096 detection points. Each element and input which, after the programming, is able to set off an alarm requires a detection point. Inputs are considered as detection points if they are programmed accordingly in the FSP???5000???RPS Programming Software.
The provided options according to EN 54???2:1997/
A1:2006 include:
- Output to fire alarm devices
- Connection conditions for the regional authorities and institutions (police, fire service) must be maintained.
- It is preferable to use the loop formation owing to the greater security of loop lines compared with stub lines.
- It is possible to combine LSN interface modules and LSN detectors on one loop or stub line.
- For a mixed connection of LSN classic elements and LSN improved elements, a maximum of 127 elements are permitted.
- Existing conventional detectors can be connected to a CZM 0004 A module. A CZM 0004 A module provides four DC primary lines (zones).